Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8538680
- Product Categories
- Friendly Links
Information Name: | Low-cost high quality factory direct HY5805Y HY5806Y |
Published: | 2012-02-06 |
Validity: | 30 |
Specifications: | HY5805Y |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | HY5805Y HY5806Y factory direct HY5801Y HY5802Y HY5803Y HY5804Y HY5805Y HY5806Y I: Overview Using the most modern microprocessors and digital signal processing technology designed, comprehensive collection of three-phase power measurement, energy accumulation, power quality analysis, fault alarm, leakage current measurement and control, digital input, output and network communication in one. HY58 Series power meters and network control unit although they are in the main measurement instrument, but way more rich and more flexible I / O capabilities, fully meet the requirements of a distributed RTU to realize remote communication, telemetry, remote control, measurement in one. Standard Statute, easy networking. HY58 Series products to meet future environmental measuring instruments, with the RS-485 serial port, open architecture to allow local area network connection, the application of Modbus communication protocol, all parameters can be obtained through the remote monitoring system. HY58 Series can set the system in the event of overvoltage, undervoltage, overcurrent, input alarm situations, passive control two relay contact output signal. 2: Product Selection HY58 Series power meters and network control unit - LCD Series HY580 * Y series three-phase multi-parameter monitoring and control of intelligent power meter specifications: HY5801Y ~ HY5805Y: 96 * 96 square; HY5806Y: 72 * 72 square) HY5801Y Measurements: three-phase voltage (phase voltage, line voltage), frequency, phase current, active power, reactive power, apparent power, power factor, active power, reactive power input: 4-way switch status input (passive signal ) Output: 2 relay outputs Communication: RS485 bus interface, Modbus protocol HY5802Y Measurements: three-phase voltage (phase voltage, line voltage), frequency, phase current, active power, reactive power, apparent power, power factor, active power, reactive power, phase angle input: 4 channel switch state input ( passive signal) Output: 2 relay outputs Communication: RS485 bus interface, Modbus protocol HY5803Y Measurements: three-phase voltage (phase voltage, line voltage), frequency, phase current, active power, reactive power, apparent power, power factor, active power, reactive power, phase angle, leakage input: 4-way switch status input (passive signal) Output: 2 relay outputs Communication: RS485 bus interface, Modbus protocol HY5804Y Measurements: three-phase voltage (phase voltage, line voltage), frequency, phase current, active power, reactive power, apparent power, power factor, active power, reactive power, harmonic measurement input: 4-way switch status input (passive signal) Output: 2 relay outputs Communication: RS485 bus interface, Modbus protocol HY5805Y Measurements: three-phase voltage (phase voltage, line voltage), frequency, phase current, active power, reactive power, apparent power, power factor, active power, reactive power, harmonic analysis, type: 4-way switch status input (passive signal) Output: 2 relay outputs Communication: RS485 bus interface, ModbuS agreement HY5806Y Measurements: 3-phase voltage (phase voltage, line voltage), frequency, phase current, active power, reactive power, apparent power, power factor, active power, reactive power HY5811Y HY5812Y HY5813Y I: Overview Using the most modern microprocessors and digital signal processing technology designed, comprehensive collection of three-phase power measurement, energy accumulation, power quality analysis, fault alarm, leakage current measurement and control, digital input, output and network communication in one. HY58 Series power meters and network control unit although they are in the main measurement instrument, but way more rich and more flexible I / O capabilities, fully meet the requirements of a distributed RTU to realize remote communication, telemetry, remote control, measurement in one. Standard Statute, easy networking. HY58 Series products to meet future environmental measuring instruments, with the RS-485 serial port, open architecture to allow local area network connection, the application of Modbus communication protocol, all parameters can be obtained through the remote monitoring system. HY58 Series can set the system in the event of overvoltage, undervoltage, overcurrent, input alarm situations, passive control two relay contact output signal. 2: Product Selection HY5811Y For various circuit voltage measurement Measurements: 3-phase voltage, input frequency: 2 passive switch state input and output: 2 programmable relay outputs Communication: RS485 bus interface, Modbus protocol HY5812Y For measurement of circuit current measurement: 3 phase current inputs: 2 passive switch status input Outputs: 2 programmable relay outputs Communication: RS485 bus interface, Modbus protocol HY5813Y For measurement of circuit current measurement: 3-phase current, input leakage: 2 passive switch status input Outputs: 2 programmable relay outputs Communication: RS485 bus interface, Modbus protocol |
Admin>>>
You are the 24482 visitor
Copyright © GuangDong ICP No. 10089450, Yueqing City Instrument Technology Co., Ltd. on All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 24482 visitor
Copyright © GuangDong ICP No. 10089450, Yueqing City Instrument Technology Co., Ltd. on All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility